Control Valve
Control Valve
Speed controller Push-lock type with Indicator
Speed setting can be checked with indicator.
Easy adjustment due to its liner characteristics.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~1.0MPa |
Check valve opening pressure | 0.05MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Speed Controller
The most standard Speed Control Valve for driving devices.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa, 0.05~0.5MPa (Low opening pressure type), 0.05~1.0MPa(JSMU) |
Check valve opening pressure | 0.05MPa, 0.02MPa (Low opening pressure type), 0.005MPa (JSMU) |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Speed Controller Large-Flow type
Large-flow type Speed Controller for driving device. Best suitable for high-speed operation cylinder.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.7MPa |
Check valve opening pressure | 0.05MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Speed Controller Low-Flow type
Low-flow type Speed Controller for driving device. Best suitable for the fine speed adjustments of low-speed cylinders..
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa |
Check valve opening pressure | 0.05MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Recessed Screw Flow Control Valve
It prevents unnecessary manual adjustments during the operations.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa |
Check valve opening pressure | 0.05MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Control Valve
2-stage Speed Controller
Industry’s First!
It enables same control as the cylinder with shock absorber. (Patent no. 5578502)
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.2~1.0MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Control Valve
Speed Control Valve SUS316 Stainless Steel
Flow control valve made of stainless steel SUS316 which has excellent anti-corrosivity
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa |
Operating temperature range | -5~60℃ (No freezing) |
Valve seat cracking pressure | 0.05MPa |
Control Valve
Speed Controller SUS303 like corrosivity
Best suitable for operating where strength is required or in corrosive atmosphere.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa |
Check valve opening pressure | 0.05MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Speed Controller PP
PP (Polypropylene) is applied for the body material to adapt to clean environment.
Specification | Details |
---|---|
Fluid Medium | Air,Other |
Operating pressure range (at0~20℃) | 0.1~1.0MPa, 0.05~0.5MPa (Low opening pressure type), 0.05~1.0MPa (PJSMU) |
Check valve opening pressure | 0.05MPa, 0.02MPa (Low opening pressure type), 0.005MPa (PJSMU) |
Operating temp. range | 0~80℃ (No freezing) |
Control Valve
Speed Controller Spatter
A fire-resistant resin (Equivalent to UL V-0) is applied for the body material to adapt to spatter environment.
Protective Cover at both needle and joint parts to protect from sparks.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa, 0.05~0.5MPa (Low opening pressure type) |
Check valve opening pressure | 0.05MPa, 0.02MPa (Low opening pressure type) |
Operating temp. range | 0~60℃ (No freezing) |
Control Valve
Speed Controller Brass
Not only the body but the release ring is made of brass, thus best suitable for high heat and spatter environments.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~1.0MPa (at 20℃ in the operating environment and fluid temperature) |
Check valve opening pressure | 0.05MPa |
Operating temp. range | 0~100℃ (HNBR), 0~120℃ (FKM)(No freezing) |
Control Valve
Constant Flow Speed Controller
This speed controller fixes the operation speed of driving device.
It is best suited for use with mass-produced dedicated machines.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa |
Check valve opening pressure | 0.05MPa, 0.02MPa (Low opening pressure type) |
Operating temp. range | 0~60℃ (No freezing) |
Control Valve
Throttle (Needle) Valve
Throttle valve controls the operation speed of a pneumatic device and the transmission of air pressure signals.
The flow rate can be adjusted while the air is flowing.
Specification | Details |
---|---|
Fluid Medium | Air |
Max. operating pressure | 0.9MPa, 1.0MPa (JNMU) |
Max. vacuum | 0.05MPa, 0.02MPa (Low opening pressure type) |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Needle Valve SUS316 Stainless Steel
Needle valve made of stainless steel SUS316 which has excellent anti-corrosivity
Specification | Details |
---|---|
Fluid Medium | Air, Water, Other chemicals (Proviso) |
Maxium operating pressure | 1.0MPa |
Vacuum | -100kPa |
Operating temp. range | -5~150℃ (No freezing) |
Control Valve
Fluororesin Needle Valve
Suitable for flow rate adjustment in semiconductor manufacturing process.
Specification | Details |
---|---|
Fluid Medium | Liquid (Conditional) |
Maxium operating pressure | 0.7MPa (at 0~60℃) |
Operating temperature range | 0~100℃ |
Operating temp. range | -5~150℃ (No freezing) |
Control Valve
Throttle (Needle)Valve PP
PP (Polypropylene) is applied for the body material to adapt to clean environment.
Specification | Details |
---|---|
Fluid Medium | Air, Water, Others such as chemicals (Conditional) |
Maxium operating pressure | 1.0MPa (at0~20℃) |
Max. vacuum | -100kPa |
Operating temperature range | 0~80℃ (No freezing) |
Control Valve
Throttle (Needle)Valve Brass
Not only the body but the release ring is made of brass, thus best suitable for high heat and spatter environments.
Specification | Details |
---|---|
Fluid Medium | Air, Water (Conditional*) |
Maxium operating pressure | 1.0MPa |
Max. vacuum | -100kPa |
Operating temp. range | 0~100℃ (HNBR),0~120℃ (FKM)(No freezing) |
Control Valve
Quick Exhaust Valve
Best suitable for high-speed drive cylinder.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.7MPa |
Min. opening pressure | 0.05MPa |
Operating temp. range | 5~60℃ (No freezing) |
Control Valve
Exhaust Port Needle Valve (Speed Control Mufflers)
This Exhaust Needle Valve controls the exhaust flow rate.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0.1~0.9MPa |
Operating temp. range | 0~60℃ (No freezing) |
Control Valve
Orifice Fittings (Tamper-Proof)
Push-in fitting type fixed orifice joint. It controls air flow.
Specification | Details |
---|---|
Fluid Medium | Air |
Maxium operating pressure | 1.0MPa |
Max. vacuum | -100kPa |
Operating temp. range | 0~60℃ (No freezing) |
Control Valve
Push-Lock Pressure Regulator with Gauge Option
The push-lock knob makes fixing and adjusting pressure easy.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0~1.0MPa |
Pressure setting range | 0.1~0.8MPa |
Indicated pressure range | 0~0.8MPa |
Accuracy (gauge) | ±5%(F.S) |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Pre-set Pressure Regulator
For applications of tamper-proof or that no pressure adjustment is needed
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | Preset pressure~1.0MPa |
Operating temperature range | 0~60℃ (No freezing) |
Pressure tolerance | ±0.025MPa (When preset pressure+0.3MPa is supplied) |
Control Valve
Pressure Controller
Pressure control valve saves compressed air consumption.
Specification | Details |
---|---|
Fluid Medium | Air |
Operating pressure range | 0~0.9MPa |
Pressure setting range | 0.2~0.6MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Check Valve
Check Valve permits the air flow in one direction but checks the flow in the opposite direction, thus keeping the output pressure at a constant level.
Specification | Details |
---|---|
Fluid Medium | Air, Water (Conditional*) |
Maxium operating pressure | 0.9MPa |
Max. vacuum | -100kPa |
Min. opening pressure | 0.01MPa or less |
Min. opening differential pressure | 0.02MPa (Metal poppet), 0.04MPa (Resin poppet) |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
Check Valve with Low cracking Pressure
Securing of air flow becomes possible at low pressure that the conventional valve does not operate.
Specification | Details |
---|---|
Fluid Medium | Air |
Max. operating pressure | 1.0MPa |
Max. vacuum | -100kPa |
Min. opening pressure | 5kPa (at25℃) |
Min. opening differential pressure | 0.01MPa |
Operating temperature range | 0~60℃ (No freezing) |
Control Valve
SUS304+PP Check Valve/Low Cracking Pressure/Water Use
Check Valve PP is applicable to water (Fluid).
PP (Polypropylene) is applied for the body material to adapt to clean environment.
Specification | Details |
---|---|
Fluid Medium | Air, Water, Others such as chemicals (Conditional) |
Max. operating pressure/span> | 1.0MPa (at0~20℃) |
Min. opening pressure | 5kPa (at25℃) |
Min. opening differential pressure | 0.01MPa |
Operating temperature range | 0~80℃, 0~60℃ (NBR)(No freezing) |
Control Valve
Silencer
Silencer, connected to the exhaust port of a device, suppresses the exhaust noise.
Specification | Details |
---|---|
Fluid Medium | Air, Water (Conditional*) |
Operating pressure range | 0~0.9MPa |
Operating temperature range | 0~60℃ (No freezing) |